		The high-density SAS-to-SAS JBOD enclosures provide capacity expansion to the 2U-profile S12S RAID systems. The J1002-R provides fault-tolerant data links across separate SAS domains. It comes with redundant power supplies and cooling modules.
- Highlights
 - Specifications
 - Accessories
 
- 
						Expansion enclosure for SAS to SAS RAID systems
						
- SAS drives for high performance and high reliability
 - SATA drives for low cost and high capacity applications
 
 - Highest density, 12 drives in 2U rack space
 - Redundant or single JBOD controllers
 - Two (2) SAS 4x wide ports per controller
 - Diagnostics LED panel
 - Proprietary enclosure service via connections (in-band) with the managing RAID enclosure
 - Path redundancy via separate SAS domains (S12S-J1002-R)
 
| Host-to-Drive Interface | JBOD Model | 
								Corresponding RAID Subsystem(s)  | 
							Configuration | Form Factor | |
|---|---|---|---|---|---|
| Model | Max. Connection | ||||
| SAS to SAS | S12S-J1002-R | 
								S12S-R1032 S12E-R1132 S12F-R1432  | 
							3 JBODs | Redundant Expander Controllers | 2U rack-mount | 
| S12F-R1840 | 6JBODs | ||||
Host Interface
- Two (2) SAS 4x wide ports per controller.
 - Proprietary enclosure service via in-band methodology
 
Drive Interface
- Twelve (12) hot swappable SAS disk drives
 - MUX kits with port selectors for dual-controller access to SATA drives
 
System Components
- Redundant or single JBOD controller configurations
 - Fault-tolerant modules interfaced through a common backplane
 - Redundant, hot swappable 460W/530W power supply units
 - Redundant, dual-speed cooling modules
 - LED diagnostics panel
 
Management
- Management of multiple enclosures via RAID firmware and/or through GUI
 - 
						Module status LED indicators:
						
- Six (6) on LED panel (1 service LED and 5 status LEDs)
 - Two (2) per drive tray
 - Three (3) per controller module (1 Ready/Failed LED and two (2) Link status LEDs)
 - One (1) per power supply unit
 - Two (2) per cooling module
 
 
Power Supply Module
| Specifications | |
|---|---|
| Power Consumption | 460W/ 530W (J1000-G/J1002-R) | 
| Input Voltage | 100VAC @ 8A/10A or 240VAC @ 4A/5A with PFC (auto-switching) | 
| Frequency | 50 to 60Hz/ 47 to 63Hz | 
Cooling Module
| Specifications | |
|---|---|
| Speed | High or low rotation speed controlled by firmware | 
| Max. Air Flow (each module) | J1002-R: 90CFM(high speed); 70.7CFM (low speed) | 
Environmental Specifications
| Humidity | 
								Operating: 5% to 95% (non-condensing) Non-operating: 5% to 95% (non-condensing)  | 
						
|---|---|
| Temperature | 
								Operating: 0° to 40°C (32°F to 104°F) Non-operating: -40° to 60°C (-40°F to 149°F)  | 
						
| Altitude | 
								Operating: Sea level to 3048m (12,000 ft.) Non-operating: Sea level to 12,192m(40,000 ft.)  | 
						
Dimensions
| Dimensions | With Forearm Handles | 
|---|---|
| Height | 88mm | 
| Width | 482mm | 
| Length | 516mm / 522mm | 
| Package dimensions: 344/390(H) x 600/575(W) x 670/780(D) mm | |
System weight
| 
								 Net Weight  | 
							
								 S12S-J1002-R 15.7kg ( 34.61 pounds )  | 
						
|---|---|
| 
								 Gross Weight  | 
							
								 S12S-J1002-R 23.6kg ( 52.03 pounds )  | 
						
Spare Parts
| 
								 | 
							IFT-9279CPSU | Power Supply Module for ES S12S-J1002-R, 530W capacity | 
|---|---|---|
| 
								 | 
							IFT-9275ECPSU | Power Supply module for ES S12S-J1000-G, 460W capacity | 
| 
								 | 
							IFT-9279CFanMod | Cooling Fan Module, for ES S12S-J1002-R | 
| 
								 | 
							IFT-9275CFanMod | Cooling Fan module, for ES S12S-J1000-G | 
| 
								 | 
							IFT-89S10J122 | SAS to SAS JBOD controller module, 2 x SAS host ports | 
| 
								 | 
							IFT-9270CmSASCab1 | SAS external, Mini SAS 4x to Mini SAS 4x (SFF-8088) cable, 50cm, for S12S-J1002-R | 
| 
								 | 
							IFT-9270CmSASCab3 | SAS external cable, MiniSAS 4X(SFF-8088) to Infiniband 4X(SFF-8470, thumbscrew type), 50 Centimeters | 
Accessories
| 
								 | 
							IFT-9279CDTray | Hard disk drive tray, exclusively for the S12S-X1032 models (identified by a light-green release button). | 
|---|---|---|
| 
								 | 
							IFT-9270CmSASCab2 | SAS external, Mini SAS 4x to Mini SAS 4x (SFF-8088) cable, 120cm | 
| 
								 | 
							IFT-9272CDTrayDmy | Dummy Drive tray, Type-II bezel | 
| 
								 | 
							IFT-9279CSlider36 | Enhanced rackmount bracket assembly for EonStor S12S-J1002-R, 23" to 36" rack depth | 
| 
								 | 
							IFT-9272CESlide28 | Enhanced Slide rail assembly, for EonStor S12S-J1000-G, 21" to 28.5" rack depth | 
| 
								 | 
							IFT-9272CESlide36 | Enhanced Slide rail assembly, for EonStor S12S-J1000-G, 25.5" to 36" rack depth | 